B1018
Circuit Description
When you first turn the ignition switch to the RUN position, the Inflatable Restraint Sensing and Diagnostic Module (SDM) performs tests to diagnose critical malfunctions within itself. Upon passing these tests IGNITION 1, 23 VLR and the deployment loop voltages are measured to make sure they are within their respective normal voltage ranges. The SDM monitors the voltages at DRIVER SIDE LOW terminal 3 and PASSENGER SIDE LOW terminal 4 to detect shorts to ground in the inflator module circuits. The service wait time is 10 minutes. Refer to Air Bags and Seat Belts / Service Precautions.
Conditions for Setting the DTC
^ The driver and passenger deployment loops are not open.
^ The driver deployment loop is not shorted to voltage.
^ The voltage at DRIVER SIDE LOW terminal 3 is more than 3.3 volts.
^ The voltage at PASSENGER SIDE LOW terminal 4 is less than 3.3 volts for 500 milliseconds.
The following tests check for this DTC. These tests occur when IGNITION 1 is within the normal operating voltage range.
^ POWER-ON-When the malfunction is detected in this test, the RESISTANCE MEASUREMENT test will not be performed.
^ CONTINUOUS MONITORING
Action Taken When the DTC Sets
^ The SDM sets DTC B1018 and also DTC B1071.
^ The SDM turns ON the AIR BAG warning lamp.
Conditions for Clearing the DTC
DTC B1018 is a latched code. You cannot clear a latched code. Repair the malfunction that set this DTC before you replace the SDM.
Diagnostic Aids
A short to ground in the Inflatable Restraint Instrument Panel (IP) module circuit can cause an intermittent condition. A DTC B1018 would be accompanied by DTC B1071. Inspect circuit 1403 and circuit 1404 carefully for cutting or chafing. Wiring pigtail damage requires replacement of the Inflatable Restraint IP module. A careful inspection of the circuits and components indicated on the DTC B1018 table is essential in order to prevent damage to the replacement Inflatable Restraint Sensing and Diagnostic Module (SDM). The diagnostic table directs the technician to note the entry value of PASSENGER SENSELO. Comparing the value of PASSENGER SENSELO can be helpful in determining if an intermittent condition exists.
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616-A Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Diagrams / Testing for Electrical Intermittents. When a wire, connector or terminal repair is requested, use the J 38125-B Terminal Repair Kit.
Test Description
The numbers below refer to the step numbers on the diagnostic table:
2. This step checks the passenger side low voltage that was measured by the Inflatable Restraint Sensing and Diagnostic Module (SDM). A reading of 3.3 V or more indicates that an intermittent condition may exist.
3. This step isolates the malfunction to one side of the Inflatable Restraint IP module yellow 2-way connector.
5. This step checks to see if there is a short to ground in circuit 1403.
7. This step determines if there is a short to ground in circuit 1404 or if there is a malfunctioning SDM.