Refrigerant Pressure Sensor / Switch: Service and Repair
REFRIGERANT LINES
Removal and Installation of Refrigerant Pressure Sensor
REMOVAL
1.Use the recovery/recycling equipment to evacuate the refrigerant.
2.Remove the engine undercover. Service and Repair.
3.Disconnect the connector, and then remove the refrigerant pressure sensor (1) from condenser (2).
CAUTION:
When working, be careful not to damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Do not reuse O-rings.
- Apply A/C oil to the O-ring of the refrigerant pressure sensor for installation.
- When recharging refrigerant, check for leaks.