High-Pressure Flexible Hose
REFRIGERANT LINES
Removal and Installation of High-Pressure Flexible Hose
REMOVAL
1.Use the recovery/recycling equipment to evacuate the refrigerant.
2.Remove the high-pressure flexible hose (1) bolt (A) from condenser (2).
3.Remove the bolt (A), and then remove the high-pressure flexible hose (1) from compressor (2).
CAUTION:
Cap or wrap the joint of the pipe with suitable material such as vinyl tape to avoid the entry of air.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Do not reuse O-rings.
- Apply A/C oil to the O-rings of the high-pressure flexible hose for installation.
- When recharging refrigerant, check for leaks.