Thermo Control Amplifier
THERMO CONTROL AMPLIFIER
Removal and Installation
REMOVAL
1.Remove evaporator. Service and Repair.
2.Disconnect thermo control amp. from evaporator.
INSTALLATION
Note the following items, and then install in the reverse order of removal.
CAUTION:
- Replace O-ring with new one. Then apply compressor oil to them when installing.
- When install the thermo control amp., set the same position before replacement.
- When remove the thermo control amp., never turn the bracket which is equipped the top of the thermo control amp.
- Check for the leakages when recharging refrigerant. Leak Test.