Inspection
WATER OUTLET
Inspection
INSPECTION AFTER REMOVAL
Water Control Valve
- Place a thread (A) so that it is caught in the valves of water control valve (1). Immerse fully in a container (B) filled with water. Heat while stirring.
- The valve opening temperature is the temperature at which the valve opens and falls from the thread.
- Continue heating. Check the continuous valve lifting toward maximum valve lift.
NOTE:
The maximum valve lift amount standard temperature for water control valve is the reference value.
- After checking the maximum valve lift amount, lower the water temperature and check the valve closing temperature.
Standard:Water Control Valve.
- If out of the standard, replace water control valve.
INSPECTION AFTER INSTALLATION
- Check for leakage of engine coolant using the radiator cap tester adapter (commercial service tool) and the radiator cap tester (commercial service tool). Inspection.
- Start and warm up the engine. Check visually that there is no leakage of engine coolant.