P0190
P0190, P0192, P0193 FRP SENSOR
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1. PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
1.Turn ignition switch OFF and wait at least 10 seconds.
2.Turn ignition switch ON.
3.Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is 11 V or more at idle.
- GO TO 2.
2. PERFORM DTC CONFIRMATION PROCEDURE
1.Start the engine ON and wait at least 60 seconds.
2.Check DTC or 1st trip DTC.
Is DTC or 1st trip DTC detected?
YES- Proceed to .
NO- INSPECTION END
Diagnosis Procedure
NOTE:
Turning the ignition switch ON with FRP sensor harness connector disconnected causes ECM to detect DTC P0190. Be sure to erase the DTC when the diagnosis procedure.
1. CHECK FUEL RAIL PRESSURE (FRP) SENSOR POWER SUPPLY-I
1.Turn ignition switch OFF.
2.Disconnect FRP sensor connector.
3.Turn ignition switch ON.
4.Check the voltage between FRP sensor harness connector terminals.
Inspection result normal?
YES- GO TO 6.
NO- GO TO 2.
2. CHECK FRP SENSOR POWER SUPPLY-II
Check the voltage between FRP sensor harness connector and the ground.
Is inspection result normal?
YES- GO TO 4.
NO- GO TO 3.
3. CHECK SENSOR POWER SUPPLY CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect ECM harness connector.
3.Check harness connector for short to power and short to ground, between the following terminals.
Is inspection result normal?
YES- Perform the trouble diagnosis for power supply circuit.
NO- Repair or replace error-detected parts.
4. CHECK FRP SENSOR GROUND CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect ECM harness connector.
3.Check the continuity between FRP sensor harness connector and ECM harness connector.
4.Also check harness for short to power.
Is inspection result normal?
YES- GO TO 5.
NO- Repair or replace error-detected parts.
5. CHECK ECM GROUND CIRCUIT
Check the continuity between ECM harness connector and the ground.
Is inspection result normal?
YES- Check intermittent incident. Intermittent Incident.
NO- Repair or replace error-detected parts.
6. CHECK FRP SENSOR SIGNAL CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect ECM harness connector.
3.Check the continuity between FRP sensor harness connector and ECM harness connector.
4.Also check harness for short to ground and to power.
Is inspection result normal?
YES- GO TO 7.
NO- Repair or replace error-detected parts.
7. CHECK FRP SENSOR
Check the FRP sensor. .
Is inspection result normal?
YES- Check intermittent incident. Intermittent Incident.
NO- Repair or replace error-detected parts.
Component Inspection
1. CHECK FRP SENSOR
WITH CONSULT
1.Turn ignition switch OFF.
2.Reconnect harness connector disconnected.
3.Start the engine.
4.Select "DATA MONITOR" mode of "ENGINE" using CONSULT.
5.Check that the "FUEL PRES SEN V" indication.
WITHOUT CONSULT
1.Turn ignition switch OFF.
2.Reconnect harness connector disconnected.
3.Start the engine.
4.Check FRP sensor signal voltage.
Is the inspection result normal?
YES- INSPECTION END.
NO- Replace FRP sensor. Exploded View.