Refrigerant Pressure Sensor / Switch: Service and Repair
REFRIGERANT LINES
Removal and Installation for Refrigerant Pressure Sensor
REMOVAL
1. Discharge the refrigerant. HFC-134A (R-134A) Service Procedure.
2. Remove the front grille. Service and Repair.
3. Reposition the LH air guide out of the way.
4. Disconnect the refrigerant pressure sensor connector (1) and remove the refrigerant pressure sensor (2) from the liquid tank
(3).
CAUTION:
Do not damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
Replace the O-ring of the refrigerant pressure sensor with a new one, then apply compressor oil to it when installing it.