Solenoid And VDC Change-Over Valve System Inspection
TROUBLE DIAGNOSIS FOR SELF-DIAGNOSTIC ITEMS
Solenoid and VDC Change-Over Valve System Inspection
INSPECTION PROCEDURE
1.SELF-DIAGNOSIS RESULT CHECK
Check self-diagnosis results.
Is the above displayed in the self-diagnosis display items?
YES - GO TO 2.
NO - Inspection End.
2.CONNECTOR INSPECTION
1. Disconnect ABS actuator and electric unit (control unit) connector.
2. Check the terminals for deformation, disconnection, looseness or damage.
OK or NG
OK - GO TO 3.
NG - Repair or replace as necessary.
3. CHECKING SOLENOID POWER AND GROUND
1. Check voltage between ABS actuator and electric unit (control unit) harness connector E33 and body ground.
2. Check resistance between ABS actuator and electric unit (control unit) harness connector E33 and body ground.
OK or NG
OK - Perform self-diagnosis again. If the same results appear, replace ABS actuator and electric unit (control unit). Removal And Installation VDC/TCS/ABS.
NG - Repair the circuit.