Power Supply and Ground Circuit For Front Air Control
Power Supply and Ground Circuit for Front Air ControlSYMPTOM:
- Heater and A/C system (if equipped) does not come on.
Step 1-4:
INSPECTION FLOW
COMPONENT DESCRIPTION
FRONT AIR CONTROL
The front air control has a built-in microcomputer which processes information sent from the temperature control dial, and various switches needed for air conditioner operation. The air mix door motor, mode door motor, intake door motor, blower motor and compressor are then controlled.
POTENTIO TEMPERATURE CONTROL (PTC)
The PTC is built into the front air control.
Step 1-2:
DIAGNOSTIC PROCEDURE
SYMPTOM: