Hazard Warning Lamps Flash When Ignition Switch Is Turned on
Hazard Warning Lamps Flash When Ignition Switch Is Turned OnDIAGNOSTIC PROCEDURE
1. CHECK BCM GROUND CIRCUIT
Check BCM ground circuit. Refer to BCS-16, "BCM Power Supply and Ground Circuit Check". Testing and Inspection
Is BCM ground circuit OK?
YES >> Replace BCM.
NO >> Repair BCM ground circuit.