DTC 0503







Front Heated Oxygen Sensor (Front HO2S) (Right bank) (DTC: 0503)
The front heated oxygen sensor (right bank) is placed into the front tube (right bank). It detects the amount of oxygen in the exhaust gas compared to the outside air. The front heated oxygen sensor (right bank) has a closed-end tube made of ceramic zirconia. The zirconia generates voltage from approximately lv in richer conditions to 0V in leaner conditions. The front heated oxygen sensor (right bank) signal is sent to the ECM. The ECM adjusts the injection pulse duration to achieve the ideal air-fuel ratio. The ideal air-fuel ratio occurs near the radical change from 1V to 0V.




DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE

OVERALL FUNCTION CHECK
Use this procedure to check the overall function of the front heated oxygen sensor circuit. During this check, a DTC might not be confirmed.

With Consult
1) Start engine and warm it up sufficiently.
2) Select "MANU TRIG" and "HI SPEED" in "DATA MONITOR" mode with CONSULT, and select "FR O2 SEN-B1" and "FR O2 MNTR-B1".
3) Hold engine speed at 2,000 rpm under no load during the following steps.




4) Touch "RECORD" on CONSULT screen.
5) Check the following.
"FR O2 MNTR-B1" in "DATA MONITOR" mode changes from "RICH" to "LEAN" to "RICH" 5 times in 10 seconds.
5 times (cycles) are counted as shown below:

cycle | 1 | 2 | 3 | 4 | 5 |
FR O2 MNTR-B1 R-L-R-L-R-L-R-L-R-L-R

R = "FR O2 MNTR-B1","RICH"
L = "FR O2 MNTR-B1","LEAN"




- "FR O2 SEN-B1" voltage goes above 0.6V at least once.
- "FR O2 SEN-B1" voltage goes below 0.35V at least once.
- The voltage never exceeds 1.0V.

OR

Without Scan Tools
1) Start engine and warm it up sufficiently.




2) Set voltmeter probes between ECM terminal (50) (sensor signal) and (25) (engine ground).
3) Check the following with engine speed held at 2,000 rpm constant under no load.
- Malfunction indicator lamp goes on more than 5 times within 10 seconds in Diagnostic Test Mode II (FRONT HEATED OXYGEN SENSOR MONITOR).
- The maximum voltage is over 0.6V at least one time.
- The minimum voltage is below 0.35V at least one time.
- The voltage never exceeds 1.0V.




WIRING DIAGRAM







DIAGNOSTIC PROCEDURE

COMPONENT INSPECTION
Front heated oxygen sensor heater




Check resistance between terminals (3) and (1).

Resistance: 2.3 - 4.3 Ohms at 25°C (77°F)

Check continuity between terminals (2) and (1), (3) and (2).
Continuity should not exist.
If NG, replace the front heated oxygen sensor.

CAUTION: Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.