Diagnostic Procedure 5
Diagnostic Procedure 5Inspecting SRS intermittent malfunction by using CONSULT-II - Diagnosis mode
1. Turn ignition switch "OFF".
2. Connect "CONSULT-II" to data link connector.
3. Turn ignition switch "ON".
4. Touch "START".
5. Touch "AIR BAG".
6. Touch "SELF-DIAG [PAST]".
7. If diagnostic codes are displayed on "SELF-DRAG [PAST]", go to step 10.
If no malfunction is detected on "SELF-DRAG [PAST]", touch "BACK" and go back to "SELECT DRAG MODE".
8. Touch "TROUBLE DIAG RECORD".
NOTE: With "TROUBLE DRAG RECORD", diagnosis results previously erased by a reset operation can be displayed.
9. Diagnostic code is displayed on "TROUBLE DRAG RECORD".
10. Touch "COPY".
11. Compare diagnostic codes to "Intermittent Malfunction Diagnostic Code Chart". Refer to "Intermittent Malfunction Diagnostic Code Chart ("SELF-DRAG [PAST]" or "TROUBLE DRAG RECORD")".
12. Touch "BACK" key of CONSULT-II until "SELECT SYSTEM" appears.
13. Turn ignition switch "OFF", then turn off and disconnect CONSULT-II, and disconnect both battery cables.
14. Repair the system as outlined by the "Repair order" in "Intermittent Malfunction Diagnostic Code Chart", that corresponds to the self-diagnostic result. For replacement procedure of component parts, refer to "REMOVAL AND INSTALLATION".
15. Go to "DIAGNOSTIC PROCEDURE 3" for final checking.