P1740
DTC P1740: Malfunction of Lockup/Select Switching Solenoid Valve
SOLENOID VALVE SYSTEM CIRCUIT
Refer to P0740.
DIAGNOSTIC FUNCTION
TCM detects abnormal operation of the lockup/select switching solenoid valve.
DESCRIPTIONS OF MONITOR METHODS
- Specified amount of current is not flown to the lockup/select switching solenoid valve because of an open or short circuit.
MONITOR EXECUTION
- Continuous
MONITOR EXECUTION CONDITIONS (OTHER MONITOR AND SENSOR)
Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
- P0741: Abnormality in lockup function
- P0746: Abnormality in hydraulic control system function
- P0841: Abnormality in line pressure sensor function
Sensor (The sensor below is determined to be normal)
- Not applicable
LOGIC FLOW CHARTS (Monitor Sequence)
DTC SET CONDITIONS
Judgment Criteria
- Lockup/select switching solenoid valve activation command (ON voltage): 1.42 volts or less (0.2 second)
- Lockup/select switching solenoid valve activation command (OFF voltage): more than 1.42 volts (0.2 second)
OBD-II DRIVE CYCLE PATTERN
Ignition switch : ON (start the engine and keep it for 10 seconds or more)
PROBABLE CAUSES
- Malfunction of valve body assembly (Faulty lockup/select switching solenoid valve)
- Damaged wiring harness and connectors
- Malfunction of TCM
PROBABLE CAUSES
- Malfunction of valve body assembly (Faulty lockup/select switching solenoid valve)
- Damaged wiring harness and connectors
- Malfunction of TCM
DIAGNOSTIC PROCEDURE
STEP 1. M.U.T.-III data list
Item 36: LU/SEL change over SOL. output
Item 37: LU/SEL change over SOL. monitor
OK: Check that the output and monitor do not differ greatly.
Q. Is the check result normal?
YES Intermittent malfunction
NO Go to Step 2.
STEP 2. Check the following connector:
- B-08 CVT assembly connector
- C-41 TCM connector
- A-09 Intermediate connector
Check the terminals for a contact status problem and internal short circuit.
Q. Is the check result normal?
YES Go to Step 3.
NO Repair the defective connector.
STEP 3. Check for open circuit and short to ground in the wiring harness between the TCM connector and the CVT assembly connector.
Between C-41 TCM connector (terminal No.14) and B-08 CVT assembly connector (terminal No.4)
Q. Is the check result normal?
YES Go to Step 4.
NO Repair the wiring harness.
STEP 4. Lockup/select switching solenoid valve single unit check
Refer to Testing and Inspection.
Q. Is the check result normal?
YES Go to Step 5.
NO Replace the valve body assembly.
STEP 5. Symptom recheck after erasing diagnosis code
Q. Is the check result normal?
YES Intermittent malfunction
NO Replace TCM.