Thermostat: Testing and Inspection
INSPECTION
THERMOSTAT CHECK
1. Immerse the thermostat in water, and heat the water while stirring. Check the thermostat valve opening temperature.
Standard value: Valve opening temperature: 82± 1.5°C (180± 3°F)
2. Check that the amount of valve lift is at the standard value when the water is at the full-opening temperature.
NOTE:
Measure the valve height when the thermostat is fully closed, and use this measurement to compare the valve height when the thermostat is fully open.
Standard value:
Full-opening temperature:95°C (203°F)
Amount of valve lift: 8.5 mm (0.33 inch) or more