Inspection Procedure 8
INSPECTION PROCEDURE 8: Wind Noise Around Door
DIAGNOSIS
STEP 1. Check the weatherstrip for holding condition.
Q. Is the weatherstrip holding firmly?
YES Go to Step 2.
NO Adjust fit of door. Refer to Adjustments.Then go to Step 5.
STEP 2. Check the weatherstrip for installation condition.
Q. Is the weatherstrip for installed properly?
YES Go to Step 3.
NO Repair or replace the weatherstrip. Then go to Step 5.
STEP 3. Check the clearance.
Q. Are the door glass and the door weatherstrip holder assembled correctly?
YES Go to Step 4.
NO Adjust the door glass and the door weatherstrip. Refer to Adjustments. Then go to Step 5.
STEP 4. Check the door.
Q. Is the door deformed?
YES Repair or replace the door. then go to Step 5.
NO Go to Step 5.
STEP 5. Retest the system.
Q. Has the wind noise been improved?
YES Return to Step 1.
NO This diagnosis complete.