Inspection Procedure 11
INSPECTION PROCEDURE 11: Rear Window Defogger Timer Function does not Operate.
CIRCUIT OPERATION
Turn ON the rear window defogger switch. If the rear window defogger does not shut off after about 16 minutes then the rear window defogger timer is malfunctioning.
TROUBLESHOOTING HINT
- Malfunction of the A/C-ECU*1
- Malfunction of the rear window defogger timer
NOTE:
*1: The A/C-ECU is incorporated in the heater control.
DIAGNOSIS
Replace the heater control.