Inspection Procedure 1
INSPECTION PROCEDURE 1: Difficult Locking and Unlocking
DIAGNOSIS
STEP 1. Check the release cable routing condition.
Q. Is the release cable routed correctly?
YES Go to Step 3.
NO Repair the release cable. Then go to Step 2.
STEP 2. Check the engagement of the liftgate latch and liftgate striker.
Q. Are the liftgate latch and liftgate striker engaged correctly?
YES Then go to Step 3.
NO Align the liftgate latch and liftgate striker (Refer to Liftgate Adjustment).
STEP 3. Retest the system.
Q. Does the liftgate lock operate normally?
YES The procedure is complete.
NO Return to Step 1.