P0840
DTC P0840: Malfunction of Secondary Pressure SensorDIAGNOSTIC FUNCTION
TCM conducts fault detection by monitoring the output voltage of the secondary pressure sensor.
DESCRIPTIONS OF MONITOR METHODS
^ The status with the fluid temperature of -20°C (-4°F) or more and with the secondary pressure sensor voltage of 4.69 volts or more continues for 5 seconds.
^ The status with the fluid temperature of -20°C (-4°F) or more and with the secondary pressure sensor voltage of 0.09 volt or less continues for 5 seconds.
MONITOR EXECUTION
^ Continuous
MONITOR EXECUTION CONDITIONS (OTHER MONITOR AND SENSOR)
Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
^ P0746: Abnormality in hydraulic control system function
^ P0841: Abnormality in line pressure sensor function
^ P0868: Secondary pressure drop
Sensor (The sensor below is determined to be normal)
^ Not applicable
LOGIC FLOW CHARTS (Monitor Sequence)
DTC SET CONDITIONS
Judgment Criteria
^ Secondary pressure sensor voltage [transmission fluid temperature: more than -20°C (-4°F)]: 4.69 volts or more. (5 seconds)
^ Secondary pressure sensor voltage [transmission fluid temperature: more than -20°C (-4°F)]: 0.09 volt or less. (5 seconds)
OBD-II DRIVE CYCLE PATTERN
Ignition switch : ON (start the engine and keep it for 10 seconds or more)
PROBABLE CAUSES
^ Malfunction of valve body assembly (Faulty secondary pressure sensor)
^ Damaged wiring harness and connectors
^ Malfunction of TCM
DIAGNOSTIC PROCEDURE
STEP 1. M.U.T.-III data list
^ Item 4: Secondary pressure sensor signal (Refer to Data List Reference Table.) Data List Reference Table
Q:Is the check result normal?
YES : Intermittent malfunction
NO : Go to Step 2.
STEP 2. Check the following connector:
^ B-08 CVT assembly connector
^ C-40 TCM connector
^ A-09 Intermediate connector
Check the terminals for a contact status problem and internal short circuit.
Q:Is the check result normal?
YES : Go to Step 3.
NO : Repair the defective connector.
STEP 3. Check for open circuit and short to ground in the wiring harness between the TCM connector and the CVT assembly connector.
^ Between C-40 TCM connector (terminal No.39) and B-08 CVT assembly connector (terminal No.7)
^ Between C-40 TCM connector (terminal No.48) and B-08 CVT assembly connector (terminal No.19)
^ Between C-40 TCM connector (terminal No.49) and B-08 CVT assembly connector (terminal No.5)
Q:Is the check result normal?
YES : Go to Step 4.
NO : Repair the wiring harness.
STEP 4. Symptom recheck after replacing the valve body assembly
Q:Is the check result normal?
YES : The procedure is complete.
NO : Replace TCM.