Inspection Procedure 2
INSPECTION PROCEDURE 2: When the Air Outlet Change over Control Knob is Moved to DEFROSTER or DEFROSTER/FOOT Position, the A/C or the Outside/Inside Air Selection Damper Control Motor does not operate.
TECHNICAL DESCRIPTION (COMMENT)
If the outside/inside air selection damper control motor does not operate normally, the inside/outside air change over damper motor system may be defective.
TROUBLESHOOTING HINTS
- Malfunction of the A/C-ECU
- Malfunction of the outside/inside air selection damper control motor
- Damaged harness wires or connectors
DIAGNOSIS
Check operation of the outside/inside air selection damper control motor.
(1)Turn the ignition switch to the "ON" position.
(2)Outside/inside air selection damper control motor switch: This is used to switch from the inside air to outside air or vice versa.
(3)Check to see that the outside/inside air selection damper control motor operates normally.
Q. Does outside/inside air selection damper control motor work normally?
YES Replace the A/C-ECU.
NO Refer to Inspection procedure 3, "Inside/outside air change over is not possible Inspection Procedure 6."