Inspection Procedure 5
INSPECTION PROCEDURE 5: Door Hard to OpenDIAGNOSIS
STEP 1.Adjust the latch and striker engagement.
Q: Is the latch and striker engagement adjusted?
YES : Go to Step 2.
NO : Adjust the latch and striker. Then go to Step 4.
STEP 2.Check for lock rod damage.
Q: Is the lock rod damaged?
YES : Repair or replace the lock rod, then go to Step 4.
NO : Go to Step 3.
STEP 3.Check the door handle flexibility (amount of movement of handle required to open door).
Q: Is the door handle flexibility good?
YES : Go to Step 4.
NO : Adjust the door handle. Then go to Step 4.
STEP 4.Retest the system.
Q: Does the door open easily?
YES : The procedure is complete.
NO : Return to Step 1.