Inspection Procedure 34
INSPECTION PROCEDURE 34: A/C system.A/C Circuit:
COMMENT
- When the A/C is "ON", the battery positive voltage is applied on the ECM
When battery positive voltage is applied to the ECM
TROUBLESHOOTING HINTS (The most likely causes for this case: )
- Malfunction of the A/C control system.
- Malfunction of the A/C switch.
- Improper connector contact, open circuit or short-circuited harness wire.
- Malfunction of the ECM
DIAGNOSIS
STEP 1. Check harness connector C-115, C-119 at ECM
Q: Is the harness connector in good condition?
YES: Go to Step 2.
NO: Repair or replace it. Then confirm that the malfunction symptom is eliminated.
STEP 2. Check the circuit at ECM connector C-119
1. Disconnect the connectors C-119
2. Turn the ignition switch to the "ON" position.
3. Measure the voltage between terminal No. 21 and ground.
- Voltage should be battery positive voltage.
4. Using a jumper wire, connect terminal No. 21 to ground.
- A/C compressor relay should turn "ON".
5. Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the voltage and A/C compressor relay condition normal?
YES: Go to Step 3.
NO: Refer to Heater, Air Conditioning And Ventilation - Manual A/C Diagnosis - Symptom Chart in heating and Air Conditioning/Testing/Diagnosis by symptom.
STEP 3. Check the circuit at ECM connector C-115
1. Disconnect the connectors C-115
2. Turn the ignition switch to the "ON" position.
3. Measure the voltage between terminal No. 83 and ground.
- Voltage should be 1 volt or less when the A/C switch is "OFF".
- Voltage should be battery positive voltage when the A/C switch is "ON".
4. Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the measured voltage within the specified range?
YES: Replace the ECM or PCM. Then confirm that the malfunction symptom is eliminated.
NO: Refer to Heater, Air Conditioning And Ventilation - Manual A/C Diagnosis - Symptom Chart in heating and Air Conditioning/Testing/Diagnosis by symptom.