Inspection Procedure 2
When the Air Outlet Changeover Control Knob is Moved to Defroster or Defroster/Foot Position, the A/C or the Inside/outside Air Changeover Damper Motor does not operate.TECHNICAL DESCRIPTION (COMMENT)
If the inside/outside air changeover damper motor does not operate normally, the inside/outside air changeover damper motor system may be defective.
TROUBLESHOOTING HINTS
- Malformation of the A/C-ECU
- Malformation of the inside/outside air changeover damper motor
- Damaged harness wires or connectors
DIAGNOSIS
STEP 1. Check operations of the outside/inside air selection damper control motor.
1. Turn the ignition switch to the "ON" position.
2. Outside/Inside Air Selection Damper Motor Switch: This is used to switch from the inside air to outside air or vice version.
3. Check to see that the outside/inside air selection damper motor operates normally.
Q: Does outside/inside air selection damper control motor work normally?
YES: Replace the A/C-ECU.
NO: Refer to Inspection procedure 3 "Inside/Outside Air changeover is not possible."