Inspection Procedure 8

When The Heater Control Knob Is Set To The "MAX COOL" Position, The Air-Conditioning Does Not Cool Sufficiently.

STEP 1. Check for refrigerant leaks.

Q: Is the refrigerant leaking?

YES: Repair. Then go to Step 4.

NO: Go to Step 2.

STEP 2. Check the water shut motor

CAUTION: When the motor stops, disconnect the battery cable.







Follow the table to check the water shut motor for correct operation.

Q: Does water shut motor work normally?

YES: Go to Step 3.

NO: Replace. Then go to Step 4.

STEP 3. Check the water shut valve controller continuity.







Follow the table to check the water shut valve controller for continuity.

Q: Is the water shut valve controller in good condition?

YES: Go to Step 4.

NO: Replace. Then go to Step 4.

STEP 4. Check symptoms.

Q: Is the cool air discharged?

YES: This diagnosis is complete. (If no malfunctions are not found in all steps, an intermittent malfunction is suspected. Refer to Introduction, How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction.)

NO: Go to Step 1.