Inspection Procedure M-3
Dome Light: Dome Light Dimming Function Does Not Work Normally.NOTE: This troubleshooting requires use of scan tool MB991502 and SWS monitor kit MB991862. For details of how to use the SWS monitor, refer to "How to use SWS monitor."
Interior Light Dimming Function:
CIRCUIT OPERATION
The ETACS-ECU operates the dome light dimming function according to the input signals from the following switches:
- Ignition switch (IG1): OFF
- Key reminder switch: ON
- Front door switches: OFF
- Driver's door lock actuator switch: LOCK or UNLOCK
TECHNICAL DESCRIPTION (COMMENT)
Is the dome lights do not dim normally, the input circuits from the switches described in "CIRCUIT OPERATION" or the ETACS-ECU may be defective.
TROUBLESHOOTING HINTS
- Malfunction of the key reminder switch
- Malfunction of the door switches
- Malfunction of the driver's door lock actuator switch
- Malfunction of the ETACS-ECU
- Damaged harness wires or connectors
DIAGNOSIS
Required Special Tools:
- MB991223: Test Harness Set
- MB991502: Scan Tool (MUT-II)
- MB991862: SWS Monitor Kit
STEP 1. Check the dome light.
If a door is opened while the dome light switch is at "door-linked" position, the dome light should illuminate.
Q: Does the dome light illuminate normally?
YES: Go to Step 2.
NO: Refer to Inspection Procedure M-1 "Dome light does not illuminate or go out normally."
STEP 2. Use scan tool to select "ECU COMM CHECK" on the SWS monitor display.
Check the ETACS-ECU.
CAUTION: To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991502. Also connect SWS monitor kit MB991862 after turning on scan tool MB991502.
1. Connect scan tool MB991502 to the data link connector.
2. Connect SWS monitor kit MB991862 to the column switch connector.
3. Turn the ignition switch to the "LOCK" (OFF) position.
4. Operate the MUT-II according to the procedure below to display "ECU COMM CHECK."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHECK."
5. Scan tool MB991502 should show "OK" on the "ETACS ECU" menu.
Q: Is "OK" displayed on the "ETACS ECU" menu?
YES: Go to Step 3.
NO: Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is impossible."
STEP 3. Check the input signal by using "DATA LIST" of the SWS monitor.
Check the input signals from the following switches:
- Ignition switch: OFF
- Driver's or front passenger's door: open Operate the MUT-II according to the procedure below to display "ETACS ECU."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "DATA LIST."
5. Select "ETACS ECU."
Check that normal conditions are displayed on the items described in the table.
Q: Does the scan tool display the items "IG SW (IG1)" and "FRONT DOOR SW" as normal condition?
YES: Go to Step 4.
NO:
- Normal condition is not displayed for "IG SW (IG1)": Refer to Inspection procedure O-2 "ETACS-ECU does not receive a signal from the ignition switch (IG1)."
- Normal condition is not displayed for "FRONT DOOR SW": Refer to Inspection procedure O-6 "ETACS-ECU does not receive a signal from the driver's or the front passenger's door switch."
STEP 4. Check the input signal (by using the Pulse Check).
Check the input signals from the following switches:
- key reminder switch
Operate the MUT-II according to the procedure below to display "PULSE CHECK."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "PULSE CHECK."
Check if scan tool MB991502 sounds or not.
Q: Does scan tool MB991502 sound when the key reminder switch is operated?
YES: Replace the ETACS-ECU. Check that the dome light dimming function works normally.
NO: Refer to Inspection Procedure P-1 "ETACS-ECU does not receive a signal from the key reminder switch."