FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Inspection Procedure 2

INSPECTION PROCEDURE 2: Does not Move Forward

COMMENT
If the vehicle does not move forward when the selector lever is shifted from "N" to "D", "2" or "L" range while the engine is idling, the cause is probably abnormal line pressure or a malfunction of the underdrive clutch or valve body.

TROUBLESHOOTING HINTS (The most likely causes for this case:)
^ Abnormal line pressure
^ Malfunction of the underdrive solenoid valve
^ Malfunction of the underdrive clutch
^ Malfunction of the valve body
^ Malfunction of the PCM

DIAGNOSIS

Required Special Tool: MB991502: Scan Tool (MUT-II)





STEP 1. Using scan tool MB991502, check actuator test item 02: Underdrive Solenoid Valve.

CAUTION: To prevent damage to scan tool MB991502, always turn the ignition switch to "LOCK" (OFF) position before connecting or disconnecting scan tool MB991502.

1. Connect scan tool MB991502 to the data link connector.
2. Turn the ignition switch to the "ON" position.
3. Set scan tool MB991502 to actuator test mode for item 02: Underdrive Solenoid Valve.
^ An operation sound should be heard from solenoid valve when solenoid valve is operated.
4. Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the solenoid valve operating properly?
YES: Go to Step 2.
NO: Repair or replace the underdrive solenoid valve. Then confirm that the symptom is eliminated.

STEP 2. Check the hydraulic pressure.
Measure the hydraulic pressure of each element when the selector lever is at the "L" range, and check if each hydraulic pressure is within the standard value.
Q: Is the hydraulic pressure within the standard value?
YES: Go to Step 3.
NO: Go to Step 4.





STEP 3. Check the underdrive clutch system.
1. Remove the valve body cover and valve body.
2. Blow 108 kPa (15psi) compressed air into the underdrive clutch oil orifice of the transaxle case, and check if the underdrive clutch piston moves and air pressure is maintained in that condition.
Q: Is the air pressure maintained?
YES: Go to Step 4.
NO: Go to Step 5.





STEP 4. Disassemble and clean the valve body.
Check the O-ring installation bolts for looseness and valve body for damage. Repair or replace the faulty parts.
Q: Is the repair possible and the symptom eliminated?
YES: Diagnosis is complete.
NO: Replace the valve body assembly. Then check the symptom. If the symptom is not eliminated, go to Step 6.





STEP 5. Check the underdrive clutch.
1. Remove the transaxle assembly.
2. Check the facing for seizure and the piston seal ring for damage and interference with the retainer. Repair or replace the faulty parts. Then check the symptom.
Q: Is the symptom eliminated?
YES: Diagnosis is complete.
NO: Go to Step 6.

STEP 6. Replace the PCM.
Q: Is the symptom eliminated?
YES: Diagnosis is complete.
NO: Start over at Step 1.