05 - Inspection Procedure
Blower Air Amount cannot be ChangedBlower Switch And Resistor Circuit:
CIRCUIT OPERATION
If the blower air amount can not be changed when the blower switch is operated, the blower switch may be defective.
TROUBLESHOOTING HINTS
- Malfunction of the resistor
- Malfunction of the blower switch
- Damaged harness wires or connectors
DIAGNOSIS
Required Special Tools:
- MB991223: Test Harness Set
STEP 1. Check that the blower motor operates when the blower switch is moved to the "HI" position.
1. Ignition switch: ON
2. Blower switch: HI
Q: Does the blower motor operate when the blower switch is moved to the "HI" position?
YES: Go to STEP 2.
NO: Refer to Inspection procedure 4 "Blower fan and motor does not turn."
STEP 2. Check the blower switch continuity.
Q: Is the blower switch continuity in good condition?
YES: Go to Step 3.
NO: Replace the blower switch. The blower motor should operate normally.
Standard Value:
STEP 3. Check the resistor resistance value.
Use an ohmmeter to measure the resistance between the terminals as indicated below. Check that the measured value is at the standard value.
Q: Is the measured value at the standard value?
YES: Go to Step 4.
NO: Replace the resistor. The blower motor should operate normally.
STEP 4. Check blower switch connector C-125 and resistor connector C-09 for damage.
Q: Are blower switch connector C-125 and resistor connector C-09 in good condition?
YES: Go to Step 5.
NO: Repair or replace the connector. Refer to Harness Connector Inspection. The blower motor should operate normally.
STEP 5. Check the wiring harness between blower switch connector C-125 and resistor connector C-09.
Q: Is the wiring harness between blower switch connector C-125 and resistor connector C-09 in good condition?
YES: Go to Step 6.
NO: Repair the wiring harness. The blower motor should operate normally.
STEP 6. Check resistor connector C-09 and blower motor connector C-08 for damage.
Q: Are resistor connector C-09 and blower motor connector C-08 in good condition?
YES: Go to Step 7.
NO: Repair or replace the connector. Refer to Harness Connector Inspection. The blower motor should operate normally.
STEP 7. Check the wiring harness between blower motor connector C-08 and resistor connector C-09.
Q: Is the wiring harness between resistor connector C-09 and blower motor connector C-08 in good condition?
YES: No action to be taken.
NO: Repair the wiring harness. The blower motor should operate normally.