64 53 515 Replacing Desiccant Insert For Air Conditioning System
64 53 515 Replacing Desiccant Insert For Air Conditioning System
Special tools required:
WARNING:
Danger of injury.
Refrigerant circuit is under high pressure.
Follow instructions for handling R 134a refrigerant.
Avoid contact with refrigerant and refrigerant fluid.
Follow safety information for handling refrigerant fluid.
IMPORTANT:
Risk of damage.
Restart engine only when A/C system
has been correctly filled.
Necessary preliminary tasks:
- Drawing off, evacuating and filling the air conditioning system are not included in the time value given for this job item
- Remove capacitor for air conditioning system
Remove protective cap (1).
Remove circlip (1) and pull out desiccant insert (2).
Installation note:
Replace sealing rings.
Use special tool 00 9 030 to mount sealing rings without damaging them.
After installation:
- Evacuate and fill air conditioning system