Air Cleaner Outlet Pipe
Air Cleaner Outlet Pipe
Removal and Installation
1. Disconnect the crankcase ventilation tube -to-Air Cleaner (ACL) outlet pipe quick connect coupling. For additional information, refer to Fuel System - General Information Quick Connect Coupling.
2. Loosen the ACL outlet pipe-to-Throttle Body (TB) clamp.
- To install, tighten to 4 Nm (35 lb-in).
3. Loosen the ACL outlet pipe-to-ACL assembly clamp.
- Remove the ACL outlet pipe.
- To install, tighten to 4 Nm (35 lb-in).
4. NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.
To install, reverse the removal procedure.