Pinpoint Tests BN: DTC U0151:00
Instrumentation, Message Center and Warning Chimes
Pinpoint Test BN: DTC U0151:00
Normal Operation
- DTC U0151:00 (Lost Communication With Restraints Control Module: No Sub-Type Information) - sets in the Instrument Panel Cluster (IPC) if data messages received from the Restraints Control Module (RCM) over the High Speed Controller Area Network (HS-CAN) are missing. For a complete list of all network messages, refer to Module Communications Network Testing and Inspection.
This pinpoint test is intended to diagnose the following:
- RCM
- IPC
PINPOINT TEST BN: DTC U0151:00
-------------------------------------------------
BN1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify that there is an observable symptom present.
- Is an observable symptom present?
Yes
GO to BN2.
No
The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
-------------------------------------------------
BN2 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: Network Test .
- Carry out the network test.
- Does the RCM pass the network test?
Yes
GO to BN3.
No
REFER to Module Communications Network Testing and Inspection.
-------------------------------------------------
BN3 RETRIEVE THE RECORDED DTCs FROM THE IPC SELF-TEST
- Check for recorded DTCs from the IPC self-test.
- Is DTC U3003:16 or DTC U3003:17 recorded?
Yes
GO to Pinpoint Test BX (U3003:16) or GO to Pinpoint Test BY (U3003:17). Pinpoint Tests BX: DTC U3003:16 Pinpoint Tests BY: DTC U3003:17
No
GO to BN4.
-------------------------------------------------
BN4 RECHECK THE IPC DTCs
- Clear the DTCs. Repeat the IPC self-test.
- Is DTC U0151:00 still present?
Yes
GO to BN5.
No
The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
-------------------------------------------------
BN5 CHECK FOR DTC U0151:00 SET IN OTHER MODULES
- Clear all DTCs.
- Ignition OFF.
- Ignition ON.
- Wait 10 seconds.
- Enter the following diagnostic mode on the scan tool: Self-Test .
- Retrieve the continuous memory DTCs from all modules.
- Is DTC U0151:00 set in the Occupant Classification System Module (OCSM)?
Yes
INSTALL a new RCM. REFER to Supplemental Restraint System Service and Repair. CLEAR the DTCs. REPEAT the self-test.
No
INSTALL a new IPC. REFER to Instrument Panel Cluster (IPC) Instrument Panel Cluster (IPC). TEST the system for normal operation.
-------------------------------------------------