Pinpoint Test S: An Individual Fog Lamp Is Inoperative
Fog Lamps
Pinpoint Tests
Pinpoint Test S: An Individual Fog Lamp Is Inoperative
Refer to Wiring Diagram Set 86, Fog Lamps for schematic and connector information. Diagrams By Number
Normal Operation
When the fog lamp relay is energized, voltage is routed through circuit CLF12 (BN/YE) to the fog lamps. Ground is provided through circuits GD120 (BK/GN) and GD123 (BK/GY) to the LH and RH fog lamps.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
PINPOINT TEST S: AN INDIVIDUAL FOG LAMP IS INOPERATIVE
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
NOTE: Make sure the bulb is good before continuing diagnostics.
-------------------------------------------------
S1 CHECK FOR VOLTAGE TO THE FOG LAMP
- Ignition OFF.
- Disconnect: Inoperative Fog Lamp.
- Place the headlamp switch in the PARKING LAMPS ON position and engage the fog lamp switch.
- Ignition ON.
- Measure the voltage between the LH fog lamp C152-A, circuit CLF12 (BN/YE), harness side and ground; or between the RH fog lamp C162-A, circuit CLF12 (BN/YE), harness side and ground.
- Is the voltage greater than 10 volts?
Yes
REPAIR the fog lamp ground circuit in question for an open. TEST the system for normal operation.
No
REPAIR circuit CLF12 (BN/YE) for an open. TEST the system for normal operation.
-------------------------------------------------