Pinpoint Tests AS: The Key-In-Ignition Warning Chime Is Inoperative
Instrumentation, Message Center and Warning Chimes
Pinpoint Tests
Pinpoint Test AS: The Key-In-Ignition Warning Chime Is Inoperative
Refer to Wiring Diagram Set 60, Instrument Cluster for schematic and connector information. Diagrams By Number
Normal Operation
The Instrument Cluster (IC) receives the key-in-ignition warning status from the Smart Junction Box (SJB) over the Medium Speed Controller Area Network (MS-CAN). The key-in-ignition warning switch (part of the ignition switch) is hardwired to the SJB through circuit CDC30 (BU/GY). When the key is inserted into the ignition lock cylinder, the key-in-ignition switch closes and supplies voltage to the SJB. The SJB monitors the door ajar input from the LH front door and the key-in-ignition switch status. When the key is inserted into the ignition lock cylinder and the driver door is open or ajar, the SJB sends the IC a chime request message to sound the key-in-ignition warning chime.
- DTC B1352 (Ignition Key-In Circuit Failure) - an on-demand DTC that sets if the SJB detects an open on the key-in-ignition switch input, circuit CDC30 (BU/GY) or if the SJB detects ignition START, RUN/START or RUN/ACC inputs without the key-in-ignition input.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Key-in-ignition switch (part of the ignition switch)
- SJB
- IC
PINPOINT TEST AS: THE KEY-IN-IGNITION WARNING CHIME IS INOPERATIVE
-------------------------------------------------
AS1 CHECK THE SAFETY BELT WARNING CHIME OPERATION
- Ignition OFF.
- Ignition ON.
- Monitor the safety belt warning chime when the ignition switch is transitioned from OFF to RUN for 6 seconds.
- Does the safety belt warning chime operate for approximately 6 seconds?
Yes
GO to AS2.
No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.
-------------------------------------------------
AS2 CHECK THE DOOR AJAR WARNING INDICATOR OPERATION
- Ignition ON.
- Open then close the LH front door while observing the message center operation.
- Does the door ajar warning display in the message center?
Yes
GO to AS3.
No
Go To Pinpoint Test AQ. Pinpoint Tests AQ: The Driver, Passenger, Rear Left, Rear Right Door Ajar Or Liftgate Warning Is Inoperative/Always On
-------------------------------------------------
AS3 RETRIEVE THE RECORDED DTCs FROM THE CONTINUOUS AND ON-DEMAND SJB SELF-TESTS
- Check the recorded DTCs from the SJB self-tests.
- Is DTC B1352 present?
Yes
GO to AS5.
No
GO to AS4.
-------------------------------------------------
AS4 CARRY OUT THE KEY-IN-IGNITION CHIME WARNING ACTIVE COMMAND USING THE SCAN TOOL
- Enter the following diagnostic mode on the scan tool: IC DataLogger.
- Select the IC key-in-ignition warning chime (CHIME_KEY) active command. Command the key-in-ignition warning chime on.
- Does the key-in-ignition warning chime sound?
Yes
GO to AS7.
No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.
-------------------------------------------------
AS5 CHECK CIRCUIT CDC30 (BU/GY) FOR VOLTAGE
- Ignition OFF.
- Insert the key into the ignition cylinder.
- Disconnect: SJB C2280b.
- Measure the voltage between the SJB C2280b-35, circuit CDC30 (BU/GY), harness side and ground.
- Is the voltage greater than 10 volts?
Yes
GO to AS7.
No
GO to AS6.
-------------------------------------------------
AS6 CHECK THE IGNITION SWITCH
- Ignition OFF.
- Disconnect: Ignition Switch C250.
- Carry out the ignition switch component test.
- Is the ignition switch OK?
Yes
REPAIR circuit CDC30 (BU/GY) for an open. CLEAR the DTCs. REPEAT the self-test.
No
INSTALL a new ignition switch. CLEAR the DTCs. REPEAT the self-test.
-------------------------------------------------
AS7 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
Yes
INSTALL a new SJB. TEST the system for normal operation.
No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
-------------------------------------------------