Pinpoint Test E: DTC B1255 Or DTC B1257




Climate Control System

Pinpoint Test E: DTC B1255 or DTC B1257

Refer to Wiring Diagram Set 55, Automatic Climate Control System for schematic and connector information. Diagrams By Number

Normal Operation

Under normal operation, the A/C ambient temperature sensor receives a ground from the HVAC module through circuit 3059 (YE/LG). A 5-volt reference voltage is supplied to the A/C ambient temperature sensor from the HVAC module through circuit 3061 (LB/OG).

- DTC B1255 Ambient Temperature Sensor Open Circuit - The module senses no voltage drop on the sensor reference voltage circuit, indicating an open circuit.
- DTC B1257 Ambient Temperature Sensor Circuit Short to Ground - The module senses excessive voltage drop on the sensor reference voltage circuit, indicating a short directly to ground.

This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- A/C ambient temperature sensor
- HVAC module



PINPOINT TEST E: DTC B1255 OR DTC B1257

-------------------------------------------------
E1 CHECK THE AMBIENT TEMPERATURE SENSOR RESISTANCE


- Ignition OFF.
- Disconnect: Ambient Temperature Sensor C132.
- Measure the resistance between the ambient temperature sensor terminals.




- Is the resistance within the specified values for these temperature ranges: 10-20°C (50-68°F), 37,000-58,000 ohms; 20-30°C (68-86°F), 24,000-37,000 ohms; 30-40°C (86-104°F), 16,000-24,000 ohms?

Yes
GO to E2.

No
INSTALL a new ambient air temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.

-------------------------------------------------
E2 CHECK THE HVAC MODULE OUTPUT VOLTAGE


- Ignition ON.
- Press the AUTOMATIC button.
- Measure the voltage between ambient temperature sensor C132-1, circuit 3061 (LB/OG), harness side and C132-2, circuit 3059 (YE/LG), harness side.




- Is the voltage between 4.7 and 5.1 volts?

Yes
INSTALL a new ambient temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation. If the code returns, INSTALL a new HVAC module. TEST the system for normal operation.

No
If diagnosing DTC B1255, GO to E3.

If diagnosing DTC B1257, GO to E5.

-------------------------------------------------
E3 CHECK CIRCUIT 3061 (LB/OG) FOR AN OPEN


- Ignition OFF.
- Disconnect: HVAC Module C228a.
- Measure the resistance between HVAC module C228a-7, circuit 3061 (LB/OG), harness side and ambient temperature sensor C132-1, circuit 3061 (LB/OG), harness side.




- Is the resistance less than 5 ohms?

Yes
GO to E4.

No
REPAIR circuit 3061 (LB/OG) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.

-------------------------------------------------
E4 CHECK CIRCUIT 3059 (YE/LG) FOR AN OPEN


- Measure the resistance between HVAC module C228a-4, circuit 3059 (YE/LG), harness side and ambient temperature sensor C132-2, circuit 3059 (YE/LG), harness side.




- Is the resistance less than 5 ohms?

Yes
GO to E7.

No
REPAIR circuit 3059 (YE/LG) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.

-------------------------------------------------
E5 CHECK CIRCUITS 3061 (LG/OG) AND 3059 (YE/LG) FOR A SHORT TOGETHER


- Ignition OFF.
- Disconnect: HVAC Module C228a.
- Measure the resistance between ambient temperature sensor C132-1, circuit 3061 (LB/OG), harness side and C132-2, circuit 3059 (YE/LG), harness side.




- Is the resistance greater than 10,000 ohms?

Yes
GO to E6.

No
REPAIR circuit 3061 (LG/OG) for a short to circuit 3059 (YE/LG). CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.

-------------------------------------------------
E6 CHECK CIRCUIT 3061 (LG/OG) FOR A SHORT TO GROUND


- Measure the resistance between HVAC module C228a-7, circuit 3061 (LG/OG), harness side and ground.




- Is the resistance greater than 10,000 ohms?

Yes
GO to E7.

No
REPAIR circuit 3061 (LG/OG) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.

-------------------------------------------------
E7 CHECK MODULE CONNECTION


- Carry out the HVAC Module Cold Boot Process. HVAC Module Cold Boot Process
- Carry out the HVAC Module On-Demand Self Test. HVAC Module Self-Test
- Operate the system.
- Does the concern return?

Yes
INSTALL a new HVAC module. TEST the system for normal operation.

No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.

-------------------------------------------------