Quick Connect Coupling
Quick Connect Coupling
Disconnect - Type I
WARNING: Do not smoke, carry lighted tobacco or have an open flame of any type when working on or near any fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.
WARNING: Do not carry personal electronic devices such as cell phones, pagers or audio equipment of any type when working on or near any fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.
WARNING: Before working on or disconnecting any of the fuel tubes or fuel system components, relieve the fuel system pressure to prevent accidental spraying of fuel. Fuel in the fuel system remains under high pressure, even when the engine is not running. Failure to follow this instruction may result in serious personal injury.
WARNING: When handling fuel, always observe fuel handling precautions and be prepared in the event of fuel spillage. Spilled fuel may be ignited by hot vehicle components or other ignition sources. Failure to follow these instructions may result in serious personal injury.
WARNING: Always disconnect the battery ground cable at the battery when working on an evaporative emission (EVAP) system or fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.
NOTICE: When reusing liquid or vapor tube connectors, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip can occur. Apply clean engine oil to the end of the tube before inserting the tube into the connector.
NOTICE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage can occur. Always plug or cap any open orifice or tube.
NOTICE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
1. If disconnecting a liquid fuel tube quick connect coupling, release the fuel system pressure. For additional information, refer to Fuel System Pressure Release Service and Repair.
2. Disconnect the battery ground cable.
3. Disconnect the quick connect coupling from the tube.
- Press the quick connect coupling release button and separate the quick connect coupling from the tube.
Connect - Type I
1. NOTE: Apply clean engine oil to O-ring seals.
NOTE: Make sure the tube clicks into place when installing the quick connect coupling onto the tube. To make sure that the tube is fully seated, pull on the coupling.
Connect the quick connect coupling onto the tube until fully seated.
2. Connect the battery ground cable.
Disconnect - Type II
WARNING: Do not smoke, carry lighted tobacco or have an open flame of any type when working on or near any fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.
WARNING: Do not carry personal electronic devices such as cell phones, pagers or audio equipment of any type when working on or near any fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.
WARNING: When handling fuel, always observe fuel handling precautions and be prepared in the event of fuel spillage. Spilled fuel may be ignited by hot vehicle components or other ignition sources. Failure to follow these instructions may result in serious personal injury.
WARNING: Always disconnect the battery ground cable at the battery when working on an evaporative emission (EVAP) system or fuel-related component. Highly flammable mixtures are always present and may be ignited. Failure to follow these instructions may result in serious personal injury.
NOTICE: When reusing liquid or vapor tube connectors, make sure to use compressed air to remove any foreign material from the connector retaining clip area before separating from the tube or damage to the tube or connector retaining clip can occur. Apply clean engine oil to the end of the tube before inserting the tube into the connector.
NOTICE: Fuel injection equipment is manufactured to very precise tolerances and fine clearances. It is essential that absolute cleanliness is observed when working with these components or component damage can occur. Always plug or cap any open orifice or tube.
NOTICE: Do not use any tools. The use of tools may cause a deformity in the clip components which may cause fuel leaks.
1. Disconnect the battery ground cable.
2. Release the lock tab on the quick connect coupling.
3. Disconnect the quick connect coupling from the fitting.
Connect - Type II
1. Release the lock tab and install the quick connect coupling onto the fitting.
2. NOTE: Apply clean engine oil to O-ring seals.
NOTE: Make sure the fitting clicks into place when installing the quick connect coupling onto the fitting. To make sure that the fitting is fully seated, pull on the coupling.
Place the lock tab into the LATCHED position.
3. Connect the battery ground cable.