FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Test Q: The Hazard Lamps Are Always On

PINPOINT TEST Q: THE HAZARD LAMPS ARE ALWAYS ON


Q1-Q2:






Q2-Q4:






Normal Operation
The smart junction box (SJB) sends a voltage reference signal to the hazard lamp switch through circuit 385 (WH/RD). When the hazard switch is pressed, the voltage signal is routed to ground through circuit 1205 (BK). The hazard switch is a momentary contact switch.

Possible Causes
- Circuit 385 (WH/RD) short to ground
- Hazard switch
- SJB