Test O: The Hazard Lamps Are Inoperative/Always On

PINPOINT TEST O: THE HAZARD LAMPS ARE INOPERATIVE/ALWAYS ON


O1-O2:






O2-O4:






O5:






Normal Operation
The smart junction box (SJB) sends a voltage reference signal to the hazard lamp switch through circuit CLS32 (BN/YE). When the hazard switch is engaged, the voltage signal is routed to ground through circuit GD116 (BK/VT). When the SJB detects a request for the hazard lamps, the SJB sends voltage to the appropriate turn lamps.

DTC B1875 - is an on-demand code that sets when the SJB detects a short to ground from the hazard lamp switch input circuit.

Possible Causes
- Circuit CLS32 (BN/YE) open or short to ground
- Circuit GD116 (BK/VT) open
- Hazard lamp switch
- SJB