Test X: The Instrument Cluster Is Inoperative
PINPOINT TEST X: THE INSTRUMENT CLUSTER IS INOPERATIVEX1:
X1-X3:
Normal Operation
With the ignition switch in the START or RUN position, the instrument cluster receives voltage from the smart junction box (SJB) through circuit CBP20 (YE/VT). When the ignition switch is in the RUN or ACC position, voltage is received from the SJB through circuit CBP23 (BN/YE). With the ignition switch in the OFF position, the instrument cluster receives its keep-alive voltage from the SJB through circuit SBP07 (WH/RD). The instrument cluster grounding is through circuit GD116 (BK/VT).
DTC B1360 - is a continuous DTC that sets if the instrument cluster detects an open on the RUN or ACC input, circuit CBP23 (BN/YE).
Possible Causes
- Fuse(s)
- Circuit CBP20 (YE/VT) open
- Circuit CBP23 (BN/YE) open
- Circuit GD116 (BK/VT) open
- Circuit SBP07 (WH/RD) open
- Instrument cluster