Test Q: The Hazard Lamps Are Always On
PINPOINT TEST Q: THE HAZARD LAMPS ARE ALWAYS ONQ1-Q2:
Q2-Q4:
Normal Operation
The smart junction box (SJB) sends a voltage reference signal to the hazard lamp switch through circuit 385 (WH/RD). When the hazard switch is pressed, the voltage signal is routed to ground through circuit 1205 (BK). The hazard switch is a momentary contact switch.
Possible Causes
- Circuit 385 (WH/RD) short to ground
- Hazard switch
- SJB