Test E: The Doors Do Not Lock/Unlock Using the Remote Keyless Entry (RKE) Keypad
PINPOINT TEST E: THE DOORS DO NOT LOCK/UNLOCK USING THE REMOTE KEYLESS ENTRY (RKE) KEYPADE1-E5:
E6-E8:
E8-E9:
Normal Operation
The smart junction box (SJB) energizes the lock or unlock relays based upon input from the RKE keypad. The RKE keypad uses circuits 78 (LB/YE), 121 (YE/BK) and 123 (RD) to send signals to the SJB by grounding the selected circuit through the RKE keypad on circuit 1205 (BK). The SJB locks or unlocks the doors and the liftgate (wagon) based on RKE keypad input.
Possible Causes
- circuit 78 (LB/YE) open or short to ground
- circuit 121 (YE/BK) open or short to ground
- circuit 123 (RD) open or short to ground
- circuit 1205 (BK) open
- RKE keypad
- SJB