Test B: Incorrect Fuel Gauge Indication
PINPOINT TEST B: INCORRECT FUEL GAUGE INDICATIONB1-B3:
B3-B6:
B6-B8:
Normal Operation
The fuel pump gauge sender receives a reference voltage signal from the instrument cluster through circuit VMC11 (YE/VT), and returns the fuel level signal to the instrument cluster through circuit RMC32 (GN/BU). As the fuel level changes, a float actuates a variable resistor that alters the fuel level signal voltage. The instrument cluster interprets this signal and commands the fuel gauge to sweep to the correct level.
Possible Causes
- circuit RMC32 (GN/BU) open
- circuit VMC11 (YE/VT) open, short to ground, or short to voltage
- fuel pump gauge sender
- fuel tank
- instrument cluster