Test C: The Luggage Compartment Lid Is Inoperative - From the Luggage Compartment Lid Switch
PINPOINT TEST C: THE LUGGAGE COMPARTMENT LID IS INOPERATIVE - FROM THE LUGGAGE COMPARTMENT LID SWITCHC1-C2:
C3-C5:
C5-C6:
C7-C8:
Normal Operation
When the smart junction box (SJB) receives an open request from the luggage compartment lid switch on circuit CPL45 (BN), or the remote keyless entry (RKE) transmitter, or the RKE keypad, the SJB supplies voltage on circuit CPL10 (GN/WH) to the luggage compartment lid latch. The luggage compartment lid latch is grounded on circuit GD171 (BK/GY).
Possible Causes
- circuit CPL10 (GN/WH) open or short to ground
- circuit CPL45 (BN) open or short to ground
- circuit GD116 (BK/VT) open
- circuit GD171 (BK/GY) open
- luggage compartment lid switch
- luggage compartment lid latch
- SJB