Test V: The Individual Reversing Lamp Is Inoperative
PINPOINT TEST V: THE INDIVIDUAL REVERSING LAMP IS INOPERATIVEV1:
V1 Continued:
Normal Operation
When the transaxle is placed in REVERSE, voltage is supplied to the reversing lamps through circuit CBP12 (GN/WH). Ground to the reversing lamps is provided through circuit GD171 (BK/GY).
Possible Causes
- Circuit CBP12 (GN/WH) open
- Circuit GD171 (BK/GY) open