Test F: DTC C1095 - ABS Hydraulic Pump Motor Circuit Failure

Pinpoint Test F: DTC C1095 - ABS Hydraulic Pump Motor Circuit Failure

Normal Operation
The operating voltage required to supply the hydraulic pump motor is in a range between 10 and 16 volts.

Fused battery voltage for the hydraulic pump is supplied to the anti-lock brake system (ABS) module, from battery junction box (BJB) fuse 36 (40A), along circuit SBB36G (GN/RD). Ground for the hydraulic pump is provided through the ABS module along circuit GD123CU (BK/RD).

Possible Causes
^ Fuse
^ Circuit open

F1-F2: