Test K: Temperature Control Is Inoperative/Does Not Operate Correctly
PINPOINT TEST K: TEMPERATURE CONTROL IS INOPERATIVE/DOES NOT OPERATE CORRECTLYK1-K2:
K2-K3:
K4-K5:
K6-K8:
K8-K10:
K10-K12:
K12-K13:
K13-K14:
K14-K15:
K15-K16:
K16-K17:
K17-K18:
K18 Continued:
Normal Operation
Under normal operation, to rotate the blend door actuator clockwise, the EMTC module or EATC module supplies voltage to the Blend door actuator motors through the door actuator feed A circuits, and supplies ground through the door actuator feed B circuits. To rotate the blend door actuator counterclockwise, the EMTC module or EATC module reverses the voltage and ground circuits.
The blend door actuator feedback resistors are supplied a ground from the EMTC module or EATC module by the blend door actuator return circuits and a 5-volt reference voltage on the blend door actuator reference circuits. The EMTC module or EATC module reads the voltage on the blend door actuator feedback circuits to determine the blend door actuator position by the position of the actuator feedback resistor wiper arm.
Door actuator feed A circuits
- LH Blend - 246 (VT)
- RH Blend - 660 (YE/LG)
Door actuator feed B circuits
- LH Blend - 245 (BN/LG)
- RH Blend 1069 (OG/LB)
Door actuator return circuits
- LH Blend 438 (RD/WH)
- RH Blend 438 (RD/WH)
Door actuator reference circuits
- LH Blend 436 (RD/LG)
- RH Blend 436 (RD/LG)
Door actuator feedback circuits
- LH Blend 437 (YE/LG)
- RH Blend 435 (YE/LB)
Possible Causes
- An open, short to voltage, ground or together in door actuator open, close, return, reference or feedback circuits
- Blend door actuator motor
- EATC module
- EMTC module
- Stuck or bound linkage or door