Exhaust Manifold RH
Exhaust Manifold-RHRemoval
1. Disconnect the battery ground cable.
2. Remove the cowl vent screen and cowl extension.
3. Disconnect the Oxygen Sensor (HO2S) electrical connector.
4. Remove the exhaust manifold to Exhaust Gas Recirculation (EGR) valve tube.
5. Remove the exhaust manifold heat shield.
^ Remove the bolts.
^ Remove the heat shield.
6. Disconnect the catalytic converter from the exhaust manifold.
^ Remove the bolts.
7. Remove the six bolts and the exhaust manifold.
^ Remove the six bolts.
8. Remove the RH exhaust manifold and the exhaust manifold gasket.
^ Discard the exhaust manifold gasket.
Installation
1. Position a new exhaust manifold gasket and install the exhaust manifold.
RH:
2. Install the bolts.
^ Tighten in the sequence shown, in two stages:
1 Stage 1: Tighten to 10 Nm (89 in. lbs.).
2 Stage 2: Tighten to 22 Nm (16 ft. lbs.).
3. Connect the catalytic converter.
^ Install the bolts.
4. Install the exhaust manifold heat shield.
^ Install the bolts.
5. Install the exhaust manifold to Exhaust Gas Recirculation (EGR) valve tube.
6. Connect the HO2S electrical connector.
7. Install the cowl vent screen and cowl extension.
8. Connect the battery ground cable.