Q2 Check Stoplight Switch
- Connect Rotunda EEC-IV Breakout Box 014-00322 or equivalent with Anti-Lock Test Adapter T90P-50-ALA to the anti-lock 55-pin connector on the wire harness.
- Turn ignition switch to ON position.
- Measure voltage between breakout box pins 32 and 60.
NOTE: Do not apply brake pedal while performing this test.
- Are there 12 volts?
YES -- Replace stoplamp switch or service circuit 511 (LG). Restore vehicle. Retest system.
NO -- Go to Q3. Q3 Check ABS Function