G1 Check Anti-Lock Brake Warning Operation
- Key OFF.
- Locate and disconnect the anti-lock brake control module.
- Key ON.
- Does the anti-lock brake warning indicator illuminate?
YES -- Go to G2. G2 Check For Short to Ground
NO -- Replace the 15A METER fuse and/or warning indicator miniature bulb if burned out. If OK, Service "Y/R" wire from instrument cluster to anti-lock relay.