A15 Check HCU FLS
- Disconnect 2-pin plug from Fluid Level Sensor (FLS) located on Hydraulic Control Unit (HCU) reservoir.
- Measure resistance between pins 1 and 2 on HCU reservoir.
- Is resistance less than 5 ohms?
YES -- Service circuit 542 or 535.
NO -- Replace hydraulic control unit reservoir.