X150 - Check HFC Circuit For Short to Ground
- Key "OFF".
- Breakout box installed, Powertrain Control Module (PCM) disconnected.
- Disconnect Constant Control Relay Module (CCRM).
- Measure resistance between the High Fan Control (HFC) test pin and test pin 40 at the breakout box. Refer to schematic.
- Is resistance greater than 10,000 ohms?
Yes -- Replace CCRM. Remove breakout box. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)
No -- Service short to ground in HFC circuit. Remove breakout box. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)