BB7 Check Circuit 498
- Disconnect valve block connector from wire harness.
- Check for continuity between breakout box pins 2 and 60.
- Is continuity present?
YES -- Service circuit 498 (PK).
NO -- Reverify code 23.
NOTE: If other codes are output, service next code.