KD2 - Check Canister Purge Solenoid Electrical Operation
- Key "ON", engine "OFF".
- Disconnect Canister Purge (CANP) solenoid.
- Connect Digital Volt/Ohm Meter (DVOM) positive test lead to VPWR circuit and negative test lead to CANP circuit at the CANP solenoid vehicle harness connector.
- DVOM on 20 volt scale.
- While observing DVOM depress and release the throttle several times to cycle output.
- Does CANP circuit cycle 0.5 volt or greater?
Yes -- Remain in Output State test mode. Go to KD3. KD3 - Check Canister Purge Solenoid For Vacuum Leaks
No -- Remove jumper. Go to KD7. KD7 - Check VPWR Circuit Voltage